209 research outputs found

    Study of Thick CZT Detectors for X-ray and Gamma-Ray Astronomy

    Full text link
    CdZnTe (CZT) is a wide bandgap II-VI semiconductor developed for the spectroscopic detection of X-rays and {\gamma}-rays at room temperature. The Swift Burst Alert Telescope is using an 5240 cm2 array of 2 mm thick CZT detectors for the detection of 15-150 keV X-rays from Gamma-Ray Bursts. We report on the systematic tests of thicker (\geq 0.5 cm) CZT detectors with volumes between 2 cm3 and 4 cm3 which are potential detector choices for a number of future X-ray telescopes that operate in the 10 keV to a few MeV energy range. The detectors contacted in our laboratory achieve Full Width Half Maximum energy resolutions of 2.7 keV (4.5%) at 59 keV, 3 keV (2.5%) at 122 keV and 4 keV (0.6%) at 662 keV. The 59 keV and 122 keV energy resolutions are among the world-best results for \geq 0.5 cm thick CZT detectors. We use the data set to study trends of how the energy resolution depends on the detector thickness and on the pixel pitch. Unfortunately, we do not find clear trends, indicating that even for the extremely good energy resolutions reported here, the achievable energy resolutions are largely determined by the properties of individual crystals. Somewhat surprisingly, we achieve the reported results without applying a correction of the anode signals for the depth of the interaction. Measuring the interaction depths thus does not seem to be a pre-requisite for achieving sub-1% energy resolutions at 662 keV.Comment: 15 pages, 11 figure

    Noise spectra of SIU-GaAs pad detectors with guard rings

    Get PDF
    This paper presents current noise characterization of circular pad Schottky barrier diodes with guard rings. The diodes were fabricated from undopped semi-insulating GaAs, SIU-GaAs, at the University of Glasgow. Current noise spectra were obtained for the detectors for two pad sizes, with reverse bias applied. Three measurements were also made on one of the detectors under forward bias. The noise spectra show an excess noise component, with a low frequency corner at less than 1kHz, and a flat region at higher frequencies. The magnitude of the white noise is approximately half that expected from shot noise theory for the given leakage currents. A fall in the magnitude of the noise was observed at 20kHz which is attributed to the dielectric relaxation time of the material

    Integrated Circuit Design in US High-Energy Physics

    Full text link
    This whitepaper summarizes the status, plans, and challenges in the area of integrated circuit design in the United States for future High Energy Physics (HEP) experiments. It has been submitted to CPAD (Coordinating Panel for Advanced Detectors) and the HEP Community Summer Study 2013(Snowmass on the Mississippi) held in Minnesota July 29 to August 6, 2013. A workshop titled: US Workshop on IC Design for High Energy Physics, HEPIC2013 was held May 30 to June 1, 2013 at Lawrence Berkeley National Laboratory (LBNL). A draft of the whitepaper was distributed to the attendees before the workshop, the content was discussed at the meeting, and this document is the resulting final product. The scope of the whitepaper includes the following topics: Needs for IC technologies to enable future experiments in the three HEP frontiers Energy, Cosmic and Intensity Frontiers; Challenges in the different technology and circuit design areas and the related R&D needs; Motivation for using different fabrication technologies; Outlook of future technologies including 2.5D and 3D; Survey of ICs used in current experiments and ICs targeted for approved or proposed experiments; IC design at US institutes and recommendations for collaboration in the future

    Resectable IIIA-N2 non-small-cell lung cancer (NSCLC): In search for the proper treatment

    Get PDF
    Locally advanced non-small cell lung cancer accounts for one third of non-small cell lung cancer (NSCLC) at the time of initial diagnosis and presents with a wide range of clinical and pathological heterogeneity. To date, the combined multimodality approach involving both local and systemic control is the gold standard for these patients, since occult distant micrometastatic disease should always be suspected. With the rapid increase in treatment options, the need for an interdisciplinary discussion involving oncologists, surgeons, radiation oncologists and radiologists has become essential. Surgery should be recommended to patients with non-bulky, discrete, or single-level N2 involvement and be included in the multimodality treatment. Resectable stage IIIA patients have been the subject of a number of clinical trials and retrospective analysis, discussing the efficiency and survival benefits on patients treated with the available therapeutic approaches. However, most of them have some limitations due to their retrospective nature, lack of exact pretreatment staging, and the involvement of heterogeneous populations leading to the awareness that each patient should undergo a tailored therapy in light of the nature of his tumor, its extension and his performance status

    Asymptotics and zeros of Sobolev orthogonal polynomials on unbounded supports

    Get PDF
    In this paper we present a survey about analytic properties of polynomials orthogonal with respect to a weighted Sobolev inner product such that the vector of measures has an unbounded support. In particular, we are focused in the study of the asymptotic behaviour of such polynomials as well as in the distribution of their zeros. Some open problems as well as some new directions for a future research are formulated.Comment: Changed content; 34 pages, 41 reference

    Large detector array and real-time processing and elemental image projection of X-ray and proton microprobe fluorescence data

    Get PDF
    Abstract A detector concept is described that integrates a large solid-angle detector array developed at Brookhaven National Laboratory and a high speed pipelined parallel processing engine developed at CSIRO for machine vision, with an embedded implementation of the Dynamic Analysis method for fluorescence spectra deconvolution and image projection, to yield a detection system capable of energydispersive detection, spectral deconvolution and real-time elemental imaging at $10 8 events per second for PIXE elemental imaging using the nuclear microprobe and SXRF elemental imaging using the synchrotron X-ray microprobe

    Block Toeplitz determinants, constrained KP and Gelfand-Dickey hierarchies

    Full text link
    We propose a method for computing any Gelfand-Dickey tau function living in Segal-Wilson Grassmannian as the asymptotics of block Toeplitz determinant associated to a certain class of symbols. Also truncated block Toeplitz determinants associated to the same symbols are shown to be tau function for rational reductions of KP. Connection with Riemann-Hilbert problems is investigated both from the point of view of integrable systems and block Toeplitz operator theory. Examples of applications to algebro-geometric solutions are given.Comment: 35 pages. Typos corrected, some changes in the introductio
    • …
    corecore